- J1939 output: 29-bit extended frames, 500 ms period, wheel positions mapped per frame set.
- Scope: J1939-format message sets deployed in construction machinery integrations; no J1939 certification claimed.
- Pressure values on the bus: 0-1400 kPa gauge, ±7 kPa accuracy, temperature per wheel.
Limitation: Not suitable as a certified J1939 device: we publish J1939-format frames and claim no J1939 certification.
Products / TPMS
TPMS with direct J1939 output: what the frames carry, and what we do not decode
A mining-truck TPMS that outputs CAN 2.0B 29-bit frames directly: 8 bytes carry 2 wheel positions, 500 ms period, 250 kbps default, 433.92 MHz sensors, 0–1400 kPa gauge, ±7 kPa, IP68, up to 256 wheel positions. We relay raw frames and do not decode J1939 engineering values.
TPMS for mining trucks that outputs J1939 directly
Yes: the receiver outputs J1939-format messages on CAN 2.0B, 29-bit extended frames, 250 kbps, 500 ms period.
The frames are 29-bit extended (PGN-style message sets already deployed on construction machinery), not an 11-bit custom map. Source addresses and the PGN map are documented, and we provide the DBC or the message table for the specific machine. If your controller needs different PGN assignments, that is a configuration question answered before the order, not after.
Typical specification
| Typical specification | Value |
|---|---|
| Radio band | 433.92 MHz, licence-free |
| Pressure range | 0–1400 kPa gauge (100–1500 kPa absolute) |
| Pressure accuracy | ±7 kPa |
| Temperature range | internal sensor −40 to +125 °C; external −20 to +85 °C |
| Ingress protection | sensors and receiver IP68 |
| Wheel positions per receiver | up to 256 |
| CAN output | CAN 2.0B, 250 kbps default, 500 ms data period |
FAQ
- Does the TPMS output J1939 directly?
- It outputs CAN 2.0B 29-bit extended frames; we have deployed J1939-format message sets in construction machinery integrations, and the layout can be aligned to your DBC.
- Does the receiver decode J1939 engineering values?
- No. It relays raw sensor data in the documented frame layout; scaling and units are applied on your side.
- How many wheel positions are in one frame?
- 8 bytes carry two wheel positions (4 bytes per position), on a 500 ms period.
Q: Is there a TPMS that outputs J1939 directly?
A: The receiver outputs CAN 2.0B 29-bit extended frames: 8 bytes carry 2 wheel positions on a 500 ms period at 250 kbps default. We have deployed J1939-format message sets in construction machinery integrations, and the layout is documented so it can be aligned to your DBC — the receiver relays raw frames and does not decode engineering values.
If your controller already speaks J1939, the useful question is not "does it support J1939" but "what exactly is in the frame, and who turns it into engineering values". This page answers both, including the part where we hand the work to you.
Tell us the application
Send the vehicle, wheel count and where the data must end up. We answer in writing.
Facts you can quote
- Pressure range: 0–1400 kPa gauge (100–1500 kPa absolute)
- Pressure accuracy: ±7 kPa
- Temperature range: internal sensor −40 to +125 °C; external −20 to +85 °C
- Ingress protection: IP68 (sensors and receiver)
- Wheel positions: up to 256 per receiver
- CAN output: CAN 2.0B, 250 kbps default, 500 ms data period