A specification written after the purchase order is a repair list. These twelve questions are the ones that change the hardware decision, so they belong in the meeting before the drawing is frozen — on port equipment, multi-axle carriers, mining trucks and agricultural implements alike. Each entry is the question, why the answer decides something, and our own answer. Two of them are no.

1. Internal sensor, or one on the valve stem?

On a port machine the valve stem is the most exposed part of the wheel: a spreader guide, a kerb, a rock in the yard finds it. A highway tractor is the opposite case — the stem is reachable, and an external sensor is quicker to fit and to replace.

Our answer: internal band sensors on port, mining and site machines, where nothing should protrude past the rim; external sensors on road vehicles where the stem stays protected. Both are on the sensor and receiver range, and the choice follows the duty cycle, not the price.

2. How many wheel positions can one receiver address?

Capacity sets the ceiling of the architecture. If the number is low, the wheels have to be split across receivers, and a split is not just more hardware — it is a data problem in the controller, which now has to merge two lists.

Our answer: 256 positions per receiver. We have had 224 positions on one machine reporting on one screen, and a 160-wheel, 20-axle beam carrier has been in service with a wheel map of that size. Capacity is almost never the reason to add hardware; the multi-axle range is built around the address space we can carry.

3. Do we need repeaters, and how many?

Repeaters are counted from the axle drawing, not from the wheel count. Anyone who answers "you will not need any" before seeing the layout is guessing, and the guess always runs in the direction that wins the order.

Our answer: we mark the radio zones on the drawing, then count. On the delivered 160-wheel beam carrier that came to two receivers and twelve repeaters for 159 sensors fitted; the same method on a six-axle machine returns one or two. The beam carrier record is the worked example.

4. Where does the receiver go?

The cab front is the obvious place and often the wrong one: the roof is steel, the loom is already dense, and the antenna ends up pointing at the rear of the machine through the structure. Mid-frame and rear positions frequently read better.

Our answer: we ask for three permitted mounting points and choose against the layout, not against habit. On port machinery the permitted points are usually the cab interior, a protected box behind the cab, and the frame at the first axle.

5. Where does the data go?

The interface decides whether the machine can act on a low tyre or the operator just gets another screen. It is also the item that is hardest to change later, because it lives in the controller and the harness.

Our answer: CAN 2.0B in 11-bit or 29-bit extended frames, RS485 with Modbus RTU, RS232, and PROFINET through a gateway. Two limits to put in writing: on Modbus RTU we are the slave, never the master; and PROFINET is not a receiver port — it is an RS232-to-PROFINET gateway, an additional component. One interface is built per unit, so it is chosen at order time.

6. Is the pressure range enough?

A tyre at 8 bar, a tyre at 1 bar and a mining tyre above 9 bar are not the same specification, and a range that is too narrow does not raise an error. It produces a sensor that reads high for the rest of its life.

Our answer: the 433.92 MHz line is quoted in two pressure classes. The standard class covers cold settings up to 9 bar; above 9 bar — where mining trucks sit — the high-pressure class applies, specified at 0–1400 kPa gauge (100–1500 kPa absolute) at ±7 kPa. Agricultural implements run far below both, around 1 bar, inside the standard class, but say so: the class changes the quote, not only the part number.

7. What temperature does it survive?

Two temperatures get confused here: the air inside the tyre, and the environment the part sits in. Brake and hub heat, wash-down water, an engine bay and a sun-baked rim are the second one.

Our answer: internal sensors −40 to +125 °C, external sensors −20 to +85 °C. Those are operating ratings for the part including its sealed cell, and they are the figures to design the installation around — not a rating for the cable or the antenna.

8. What IP rating, and on which part?

Ingress ratings get copied from one product to another in a catalogue. A receiver in a sealed box does not make the sensor sealed, and a rating on one radio line says nothing about the other one.

Our answer: IP68 on the 433.92 MHz line — sensors, receivers and repeaters. The Bluetooth line for two-wheelers is IP67 and stays at IP67. IP68 on our parts is an immersion test result, not a certificate, and we present it as a test result.

9. Can the battery be replaced?

This is the question that decides the service plan. A replaceable cell is a scheduled task; a sealed one is a replacement part.

Our answer: no. The internal sensor's cell is sealed inside the housing and cannot be replaced in the field. When it is finished, the sensor is replaced, and the planning figure is the five to six years we quote for the sealed part. The external sensor is the opposite — that cell is replaceable and swapping it needs no re-pairing. If your maintenance model requires a field-replaceable cell on an internal sensor, this is the one item we do not offer, and it is better to hear it now than in year five.

10. Which certifications do you hold?

A logo wall is not an answer. There are only three states — held, in progress, and not available — and the second one must never be written as the first.

Our answer: CE-RED is in progress. The certificate is not in hand, so no product is described as having it, and we do not send a document we do not hold. ATEX and IECEx: we do not do them — there is no explosion-proof version, and if the machine works in a classified zone we are the wrong supplier. E-mark and FCC are not held either. Every item, with its status, is on the certification status page.

11. Does a tyre change or a sensor replacement need re-pairing?

This is the cost nobody quotes. The first tyre change shows whether the system can be serviced by the customer's own fitters.

Our answer: a tyre change that puts the same sensor back on the same wheel needs nothing. A sensor replaced with a new one carries a new ID and must be registered to its wheel position — with the handheld tool or through the receiver, on the machine. The wheel map is part of the delivery for exactly this reason: with that list the fifth year of service is a registration, without it the fifth year is a commissioning visit.

12. Can the supplier show measured data?

"Tested" is not data. The questions are what was logged, on which machine, and whether the log is per wheel position.

Our answer: we hold packet-loss logs per wheel position, radio range measured through a steel rim, and commissioning records from machines in service. One log is published in full on the packet loss by wheel position page: a reach stacker, six sensors, 4,189 valid packets. A supplier who cannot produce a log of that shape has not measured anything — they have fitted parts.

What goes into the specification

ItemValue
Pressure0–1400 kPa gauge (100–1500 kPa absolute), ±7 kPa
Temperatureinternal −40 to +125 °C; external −20 to +85 °C
SealingIP68 on the 433.92 MHz line; IP67 on the BLE line
Wheel positionsup to 256 per receiver
InterfacesCAN 2.0B (11-bit or 29-bit extended frame), RS485 Modbus RTU as slave, RS232, PROFINET through a gateway
Batteryinternal sealed and not replaceable; external replaceable
CertificationCE-RED in progress; no ATEX, no E-mark, no FCC

Two rows of that table are the ones we cannot fill the way a buyer would prefer: a sealed battery and no ATEX. They stay in the table because a specification that omits them is not a specification, it is a brochure.

Send the drawing, not the wish list

Four inputs change our answer: the axle layout, the cold inflation pressure, the interface your controller already speaks, and whether commissioning happens empty or loaded. With those four, the reply is a sensor count by axle, a receiver and repeater count with mounting points, and a wheel map template.

Send them and the answer is a configuration for that machine.