Recursos / Integration

TPMS en PROFINET - mediante pasarela RS232-PROFINET

· 7 min de lectura

Start with the honest sentence

Our receiver does not have a PROFINET port. A receiver is built with one interface, chosen at the

factory — CAN, RS232, RS485 or Modbus RTU — and none of those is PROFINET.

If your controller is a Siemens PLC on a PROFINET network, the route is:

`sensors → receiver (RS232) → RS232-to-PROFINET gateway → your PLC`

That is not a workaround to be embarrassed about. It is a normal architecture for a sensor that has a

serial output, and it keeps the tyre hardware standard instead of creating a special variant. What

matters is that both sides know it is a gateway, so nobody plans for a native PROFINET node.

Why this path is usually the right one

Three reasons, in order of importance:

1. The alternative is a new interface variant of the receiver. That is a development project for a

small volume. The gateway is a part you can buy today.

2. The gateway isolates the two worlds. If the PROFINET side is re-configured, replaced or moved to

another machine, the tyre hardware is untouched — and vice versa.

3. You keep the tyre data on the machine network. The PLC reads it as I/O, the machine's own logic

decides what to do (derate, alarm, log), and the vehicle's functions stay in your controller.

What the gateway has to do (check these before you buy)

Most RS232-to-PROFINET gateways are similar; these are the differences that matter.

ItemWhy it matters
Serial side: TTL or RS232The receiver's serial level is 3.3 V TTL by default, RS232 on request — order the level on the receiver, not at the gateway.
Baud rate supportOur receiver's baud rate is confirmed per project, not published. Give the gateway's supported range early so both ends are ordered coherently.
Frame handlingThe gateway must pass the receiver's frame through (or map it). Decide whether the PLC parses the frame itself or the gateway presents registers.
Data directionSome gateways are strictly I/O (PLC reads); some support writes. The tyre data is read-only for the PLC, so read is enough.
Cycle timeThe receiver publishes on a 500 ms cycle. A gateway refreshing much faster than that buys you nothing, and one refreshing at 2 s loses data. Match it to 500 ms.
DiagnosticsYou want a way to see "gateway up but no frames from the receiver" as a distinct state. Otherwise a serial problem looks like a network problem.

Two integration styles, pick one

Style A — the PLC reads a block of registers from the gateway. The gateway presents the serial data

as I/O. The PLC treats it like any other PROFINET device. Simplest, and what most machine builders

want.

Style B — the gateway just passes the serial frame, the PLC parses it. More control, more PLC code.

Only worth it if the PLC already has a parser for a similar device, or if the gateway's register layout

does not match how you want wheel positions arranged.

For a first project, A. You can always move to B later without changing the tyre hardware.

What to decide before you order anything

1. Receiver level — TTL or RS232 (order it on the receiver, remember).

2. Baud rate — ask the gateway's supported range, then agree the receiver's configuration.

3. Who parses the frame — gateway registers, or the PLC.

4. Wheel position mapping — how a register index maps to "left front, inner rear, third axle". Do

this in your PLC's naming, not in ours.

5. Alarm logic — threshold, how many consecutive bad reads before an alarm, and what to do when a

position simply stops reporting. That last state is the one people forget.

The three things that go wrong

SymptomUsual causeFix
Gateway online, PLC sees zerosBaud rate or level mismatch between receiver and gatewayConfirm both ends on the same configuration sheet before ordering
Values plausible but wrongFrame layout assumed instead of read from the documentUse the frame description supplied with the unit
A position goes missing and nobody noticesNo `last seen` logic in the PLCTimestamp each position; alarm on staleness, not only on low pressure

Where this fits commercially

This is a small but high-value configuration: the customer is usually a **machine builder or a plant

integrator** who already has a PROFINET network and wants the tyre data on it. The gateway is a

separate item in the quote, and it belongs in the bill of materials next to the receiver — not

hidden inside a sensor price.

If you are planning this, tell us the PLC family and whether the network is new or existing. We will

confirm the receiver configuration in writing, and we will name the gateway as a separate line so the

bill of materials is honest from the start.

See the receiver configurations on the product pages, the interface options on

the TR100 page, or go straight to the

PLC integration page for the non-PROFINET case. To confirm a configuration for

your PLC, send us the details.